HCTE-WMBT003 is a high-precision intelligent test platform for wall-mounted boiler components (pressure parts, heat exchangers, burners, valves, sensors). It integrates ±0.1%FS pressure detection, multi-parameter analysis (temperature, flow), and real-time data visualization, compliant with CE (LVD/EMC) and ISO 9001. Ideal for Singaporean R&D labs, production QC, and international certification bodies.
Place of Origin :
ChinaBrand Name :
HONGCECertification :
calibration certificate(cost additional)Model Number :
HCTE-WMBT003Price :
NegotiatableMOQ :
1 setDelivery Time :
30 daysPayment Terms :
L/C, T/TPackaging Details :
PlywoodSupply Ability :
10 set per monthWall Mounted Boiler Parts Tester ±0.1%FS Pressure Precision Multi-Component Testing
| Standard | Clause | Test Coverage |
| ISO 9001:2015 | Quality management | Design, production, after-sales |
| CE (LVD 2014/35/EU) | Low-voltage safety | 220V±10% power supply stability |
| CE (EMC 2014/30/EU) | Electromagnetic compatibility | Reduces interference; resists external EMI |
| ASME BPVC | Pressure vessel safety | 0-10MPa pressure cycle testing |
| Parameter | Technical Details |
| Model | HCTE-WMBT003 |
| Pressure | |
| Detection Range | 0–10MPa |
| Accuracy | ±0.1%FS |
| Temperature | |
| Detection Range | -40℃–200℃ |
| Accuracy | ±0.5℃ |
| Flow | |
| Detection Range | 0–500L/min |
| Accuracy | ±0.2%FS |
| Control & Data | |
| Control Mode | PLC + 10-inch Touchscreen HMI |
| Data Storage | ≥10,000 Records (USB/Cloud Export) |
| Environment & Power | |
| Ambient Temperature | 10–35℃ (Singapore Climate Adaptation) |
| Protection Rating | IP40 (Cabinet) / IP30 (Sensor) |
| Power Supply | AC220V±10%/50Hz, 300W |
| Physical | |
| Dimensions (L×W×H) | 1200×800×1500mm (Modular Design) |
| Weight | 80kg (Main Unit) |
Hot Tags :