AEEDL-002 is developed based on GB/T7725-2022, accurately measures air volume (±1.0%), heating capacity (±3.0%) and other parameters, integrates intelligent control, 72h stable operation and lifetime maintenance, supports CNAS certification, and provides high-precision data for the development and testing of room air conditioners to ensure compliance and reliability.
Place of Origin :
CHINABrand Name :
HONGCECertification :
Calibration Certificate(cost additional)Model Number :
AEEDL-002Price :
NegotiableMOQ :
1 SetDelivery Time :
90 DaysPayment Terms :
L/C, T/TPackaging Details :
PlywoodSupply Ability :
1 Set per monthAir Conditioning Enthalpy Difference Comprehensive Performance Test Room Air Volume 250-2500m³/H 1.8-14kw Heating Capacity
Product Introduction
AEEDL-002 uses the air enthalpy difference method to conduct a full range of tests on the room air conditioner's outlet static pressure (-50~450Pa, ±0.1%), circulating air volume (250~2500m³/h, ±1.0%), cooling/heating capacity (1.8~4/14KW, ±3.0%) and power consumption (0.6~6KW, ±0.5%). The system has been optimized to quickly reach a stable working condition (reduce waiting) and run continuously for ≥72h (error <3%). The "fool-style" touch screen automatically collects and processes data, and the component life exceeds 20 years, which is suitable for long-term high-frequency use. Before delivery, it is compared with the national laboratory (data difference <3%), supports CNAS certification, and the output results are directly used for international standard assessment, helping air-conditioning companies to efficiently complete the R&D, quality inspection and certification processes.
Product Features
International reference standards
Product use
Test objects and test items
Test objects: room air conditioners (1-5 hp), split air conditioners, variable frequency air conditioners.
Test items: circulating air volume, outlet static pressure, cooling/heating capacity, power consumption, energy efficiency ratio (EER/COP), stable operation time.
After-sales service
Lifetime maintenance: equipment relocation, upgrading, and transformation to ensure compliance with the latest national standards.
Technical support: 24h response, 48h troubleshooting, 72h on-site service.
Certification service: national laboratory comparison, CNAS certification procedural guidance.
| Item | Technical Details |
| Model | AEEDL-002 |
| Test Standard | GB/T7725-2022, ISO5151, ASHRAE 37 |
| Airflow Range | 250-2500m³/h (Room AC) |
| Airflow Precision | ±1.0% |
| Static Pressure Range | -50-450Pa (Outlet/External) |
| Static Pressure Precision | ±0.1% |
| Cooling Capacity Range | 1.8-4KW (±3.0% Precision) |
| Heating Capacity Range | 1.8-14KW (±3.0% Precision) |
| Power Consumption Range | 0.6-6KW (±0.5% Precision) |
| Continuous Operation | ≥72h (Error <3%) |
| Sensor Accuracy | <3% vs National Lab Data |
| Operation Interface | Touchscreen, Auto Data Acquisition/Processing |
| Service Life | ≥20 Years (With Routine Maintenance) |
| Certification Support | CNAS, National Lab Evaluation |
| Dimensions | Customized (Lab Layout-Based) |
| Weight | Customized (Including Test System) |