Product introduction:
The high-voltage bushing vacuum oil filling and insulation oven is a special equipment used in the manufacturing process of high-voltage bushings. Its main function is to provide a high-temperature environment, so that the oil can undergo vacuum treatment and insulation under high temperature to ensure the quality and performance of the oil. This equipment adopts advanced vacuum oil filling technology, which can heat, insulate and fill the oil in a high vacuum environment, effectively remove the gas and moisture in the oil, and improve the insulation performance and service life of the oil. At the same time, this equipment also has the characteristics of high degree of automation, simple operation, and safe and reliable, which can greatly improve production efficiency and product quality. The high-voltage bushing vacuum oil filling and insulation oven is suitable for the manufacturing of various high-voltage bushings, such as cable bushings and transformer bushings. It is widely used in fields such as power, electronics, and communications, and is one of the essential and important equipment in the manufacturing process of high-voltage bushings.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
30 daysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE-VTE-011Detection standards:
GB/T 2900.10-2013, the national standard "Electrical Terminology - Cables" is by TC232 (National Electrical Terminology Standardization Technical Committee), and this standard is equivalent to the IEC international standard: IEC 60050-461:2008.
GB/T 7354-2018, the national standard "High Voltage Test Technology - Partial Discharge Measurement" is under the jurisdiction of TC163 (National High Voltage Test Technology and Insulation Coordination Standardization Technical Committee), with the competent department being the China Electrical Apparatus Industry Association. This standard is modified and adopted from the IEC international standard: IEC 60270:2000.
GB/T 13032-2008
IEEE 386-2014, this standard specifies the requirements in terms of electrical performance, mechanical performance, and environmental adaptability of high-voltage bushings (including oil-filled, gas-filled, oil-free, and gas-insulated bushings), and is one of the important standards for the performance evaluation of high-voltage bushings.
IEC 60050-363:2011, this standard stipulates the technical requirements, test methods, inspection rules, packaging, transportation, and storage requirements of high-voltage bushings, which is similar to the GB/T 2900.10-2001 standard.
Detection items:
Vacuum degree detection: To detect the vacuum degree inside the oven to ensure that the oil is heated and insulated under a vacuum environment.
Temperature detection: To detect the temperature inside the oven to ensure that the oil is heated and insulated within the set temperature range.
Humidity detection: To detect the humidity inside the oven to ensure that the oil is processed in a dry environment.
Oil quality detection: To conduct quality detection on the oil inside the injected high-voltage bushing, including indicators such as the viscosity, acidity and alkalinity, and water content of the oil.
Insulation performance detection: To conduct electrical performance detection on the high-voltage bushing, including indicators such as insulation resistance and dielectric loss, to evaluate the insulation performance of the oil.
Appearance quality detection: To detect the appearance quality of the high-voltage bushing, including indicators such as surface quality and dimensions.
Mechanical performance detection: To detect the mechanical performance of the high-voltage bushing, including indicators such as tensile strength and bending performance.
Test objects:
Vacuum degree: Test the vacuum degree inside the oven to ensure that it reaches the preset standard, so as to ensure that the oil is heated and insulated in a vacuum environment.
Temperature: Test the temperature inside the oven to ensure that it reaches the preset temperature range, so as to ensure that the oil is heated and insulated within the set temperature range.
Oil quality: Conduct quality testing on the oil inside the injected high-voltage bushing, including indicators such as the viscosity, acidity and alkalinity, and water content of the oil, to ensure that the oil quality meets the requirements.
Insulation performance: Conduct electrical performance testing on the high-voltage bushing, including indicators such as insulation resistance and dielectric loss, to evaluate the insulation performance of the oil.
Appearance quality: Conduct testing on the appearance quality of the high-voltage bushing, including indicators such as surface quality and dimensions, to ensure that it meets the appearance requirements.
Mechanical performance: Conduct testing on the mechanical performance of the high-voltage bushing, including indicators such as tensile strength and bending performance, to ensure that it meets the mechanical performance requirements.
Hot Tags :