Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment

Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment

AEEDL-001 air conditioning enthalpy difference test room adopts air enthalpy method to accurately measure the rated cooling/heating capacity, air volume, power consumption and other parameters of air conditioners. It integrates explosion-proof safety alarm, anti-static grounding and automatic exhaust system, and complies with GB/T7725, ISO5151 and other standards. It provides full working condition simulation and safety protection for air conditioning research and development and testing, and is suitable for testing new refrigerants such as R32/R290.

  • Place of Origin :

    CHINA
  • Brand Name :

    HONGCE
  • Certification :

    Calibration Certificate(cost additional)
  • Model Number :

    AEEDL-001
  • Price :

    Negotiable
  • Minimum Order Quantity :

    1 Set
  • Delivery Time :

    90 Days
  • Payment Terms :

    L/C, T/T
  • Packaging Details :

    Plywood
  • Supply Ability :

    1 Set per month

Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment

 

Product Introduction

As the core platform for air conditioning performance testing, AEEDL-001 uses the air enthalpy difference method to achieve multi-dimensional parameter measurement: indoor and outdoor cabin simulation - 20℃~50℃ temperature range, 10%~95% RH humidity, ±0.1℃ temperature control accuracy meets the strict requirements of GB/T7725 for the enthalpy difference method. The equipment is equipped with 6 R32 infrared detectors (3 inside and 3 outside), real-time monitoring of 0~100% LEL concentration, two-level early warning linkage ventilation, power off and fire emergency lighting, to ensure the safety of testing flammable and explosive refrigerants such as R32/R290. The modular design is compatible with split-type, multi-split and other models, supports maximum/minimum operation of cooling/heating, freezing/condensation and other extreme working conditions, covers the entire process from R&D to mass production. Air conditioning performance evaluation, data can be directly used for GB, ISO, ASHRAE and other domestic and foreign certifications.

 

Product Features

  • High-precision measurement: Inlet air dry/wet bulb temperature ±0.10℃ control, relative humidity ±2% RH measurement, meeting the accuracy requirements of international standards for enthalpy difference method.
  • Explosion-proof safety system: Two-level warning (10%/20% LFL) linkage ventilation, power off, 10-minute rapid dilution of leaked refrigerant, suitable for testing high-risk refrigerants such as R32/R290.
  • Full-condition simulation: -20℃~50℃ wide temperature range (optional -40℃), 10%~95% RH humidity, support maximum/minimum operation, freezing/condensation and other extreme conditions.
  • Intelligent linkage control: Fresh air/exhaust damper, explosion-proof fan and alarm system automatically respond to ensure safe and controllable gas concentration in the cabin.
  • Anti-static design: Independent grounding (<1.0Ω), anti-static wheel and rubber seal, eliminate hidden dangers of static sparks, suitable for sensitive electronic testing.
  • International standard compatibility: Supports GB/T, ISO, JIS, ASHRAE and other systems, and the output data is directly used for domestic and foreign certification applications.

 

International reference standards

  • GB/T7725-2004: defines the test process, accuracy and data processing of the enthalpy difference method to ensure domestic market access.
  • ISO5151:2014: International air conditioning performance rating standard, covering air volume, EER/COP and other parameter measurements.
  • ANSI/ASHRAE37-2013: American Refrigeration Association standard, standardizing enthalpy difference laboratory environmental control and safety protection.
  • IEC60079-14:2013: Explosion-proof electrical ventilation protection standard, guiding the design and installation of laboratory explosion-proof equipment.

 

Product use

  • Air conditioning research and development: cooling/heating capacity optimization, low temperature heating verification, APF energy efficiency test (including variable frequency multi-conditions).
  • Quality inspection: air volume, power consumption, condensation/freezing fault simulation before leaving the factory, third-party certification compliance inspection.
  • Refrigerant safety: R32/R290 leakage protection, explosion-proof performance verification, and adaptability to new environmentally friendly refrigerant testing.
  • Energy efficiency certification: Meet the testing requirements of energy efficiency standards in GB, ErP, DOE and other regions.

 

Test objects and inspection items

Test objects: household (1~5 HP), commercial (10~50 HP) air conditioners, special (explosion-proof/low temperature) air conditioners, including R32/R290 refrigerant models.

Inspection items: rated cooling/heating, air volume, power consumption, APF; freezing/condensation/condensate removal; refrigerant leakage alarm response; grounding resistance/explosion-proof system reliability.

 

After-sales service

Standard support: provide GB/ISO/ASHRAE test solutions and assist in certification application.

Customized transformation: expand temperature range (-40℃), increase workstations (double cabins in parallel).

Safety training: explosion-proof/anti-static operation training (online/offline).

Warranty maintenance: 1 year warranty, lifetime explosion-proof component upgrade.

 

Technical Parameters

 

Item Technical Details
Model AEEDL-001
Test Method Air Enthalpy Difference Method
Temperature Range -20℃~50℃ (Indoor/Outdoor, -40℃ Optional)
Humidity Range 10%~95%RH (Control Precision ±3%RH)
Temperature Control ±0.10℃ (Inlet Dry/Wet Bulb, Class A Sensor)
Gas Detection 0~100%LEL (R32/R290, Error ±3%FS, 6 Detectors)
Ventilation Capacity 10-Minute Full Leakage Gas Dilution
Safety Alarms Two-Level Warning (10%/20%LFL), Linked with Power Off/Ventilation
Static Pressure -150~550Pa (EJA120E, Precision ±0.1%)
Airflow Measurement ±0.1% (EJA110E Nozzle Differential Pressure)
Power Supply 3φ 380V, 120kVA (Variable Frequency Voltage Regulation, Voltage Precision ±2%)
Dimensions 8000×4000×3500mm (Including Control Room)
Weight 15000kg (Including Safety System)
Fire Lighting 30-Minute Backup Power, Explosion-Proof Emergency Lighting
Grounding Resistance <1.0Ω (Independent Grounding, Stainless Steel Floor)
Explosion-Proof Ex IIB T4 (Electrical Components, Compliant with IEC60079-14)
Data Output RS-232c/RS485, Real-Time Temperature/Humidity/Pressure Data Recording
Leave a message
Polyester Powder Coating for industry or architectures
Submit
Categories
Related Products
Related Products
Air Conditioning Enthalpy Difference Lab
Air Conditioning Enthalpy Difference Test Room International Standard Air Conditioning Performance Test Equipment
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
heating capacity test
Air Conditioning Enthalpy Difference Comprehensive Performance Test Room Air Volume 250-2500m³/H 1.8-14kw Heating Capacity
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
Air Conditioning Enthalpy Difference Lab
Air Conditioning Performance Enthalpy Difference Laboratory 6000-48000btu/H Cooling Capacity
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
Appearance of air conditioning enthalpy difference chamber
Air Conditioning Enthalpy Difference Chamber Comprehensive Performance Test Temperature And Humidity ±0.1℃ Precise Control
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
Air Conditioning Enthalpy Difference Lab
Air Conditioning Enthalpy Difference Laboratory Temperature Control Accuracy ±0.1℃ Air Volume 200-5000m³/H
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
Appearance of air conditioning enthalpy difference chamber
Fresh Air Enthalpy Difference Laboratory Gb/T21087-2020 Compliant Enthalpy Exchange Efficiency ±1%
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
Appearance of air conditioning enthalpy difference chamber
Gb/T7725 Air Conditioning Enthalpy Difference Test Room Multi-Parameter Simultaneous Measurement
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
Air Conditioning Enthalpy Difference Test Laboratory
Air Conditioning Enthalpy Difference Test Room Multi-Refrigerant Air Conditioning Performance Test System
IPX1~8 waterproof test system includes vertical drip rain testing machine, oscillating tube tester for IPX3 and IPX4, spray nozzle,&nbsp; handheld jet nozzle, smart water supply and control system, IPX8 water tightness pressure tester and tiltable rotating stage.
View details
:
Committed to the research and development, manufacturing and sales of laboratory testing instruments and production line testing systems
Get a free quote

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

whatsApp