Gas Fired Boiler Aging Tester Gb6932/Gb2665 Compliance 0–100℃ (0.5%F.S)
Product Introduction:
Gas boiler aging tests face challenges: manual parameter drift (≥1% error), disjointed workflows (heating/sanitary tested separately), and safety blind spots (no integrated leakage protection). WMB-003 redefines reliability:
- Automated Aging Simulation: PLC + PC control replicates 5,000+ hours of operational stress (e.g., 1-40L/min flow cycles for heating systems), detecting early-stage component degradation.
- 0.5%F.S Precision: Monitors water pressure (0-1.6MPa), gas pressure (0-10kPa), and temperature (0-100℃) with ±0.5% accuracy, ensuring energy efficiency compliance with GB2665.
- Safety-Centric Design: Built-in leakage protection and overload shutdown prevent test failures, safeguarding lab/production line safety.
The system auto-generates aging reports with wear trends, accelerating design optimization and pre-market certification.
Product Features:
- Dual GB Standard Compliance: Aligns with GB6932-2015 (aging test conditions) and GB2665-2015 (energy efficiency validation).
- 0.5%F.S Precision Matrix:
- Water pressure: 0-1.6MPa (0.5%F.S)
- Gas pressure: 0-10kPa (0.5%F.S)
- Temperature: 0-100℃ (0.5%F.S)
- Full-Range Aging Tests:
- Sanitary Aging: 1-30L/min flow cycles (simulating hot water demand).
- Heating Aging: 1-40L/min flow cycles (mimicking heating load).
- Smart Control & Safety:
- PLC presets aging profiles; touchscreen adjusts pressure/flow in real time.
- Leakage protection + automatic shutdown (activates at 0.05MPa pressure anomalies).
- Durable Construction: Industrial-grade valves/sensors withstand 10,000+ aging cycles, reducing maintenance by 40%.
- Data-Driven Reports: Stores aging curves and wear data, supporting ISO/GB certification audits.
International/Regional Standards Compliance
Standard |
Scope |
Key Test Items |
GB6932-2015 |
Gas-fired instantaneous water heaters |
Aging test conditions (flow/pressure cycles) |
GB2665-2015 |
Energy efficiency for gas boilers |
Thermal efficiency validation during aging |
Product Applications
- R&D Validation: Manufacturers test component durability (e.g., heat exchangers) under simulated 5-year wear, optimizing designs for Singapore’s climate.
- Production Line QC: Mass aging tests (30+ units/day) identify early failure modes, reducing post-sale defects by 35%.
- Third-Party Inspection: Certification bodies (e.g., Singapore’s SFA) use it for pre-market approval, with reports accelerating COC (Certificate of Conformity) issuance.
Technical Parameters
Parameter |
Specification |
Model |
WMB-003 |
Pressure |
|
Compressed Air Pressure |
0.5–0.8MPa |
Inlet Water Pressure |
0–1.6MPa (0.5%F.S) |
Gas Pressure |
0–10kPa (0.5%F.S) |
Flow |
|
Sanitary Flow Range |
1–30L/min (aging test) |
Heating Flow Range |
1–40L/min (aging test) |
Temperature |
|
Outlet Water Temp. |
0–100℃ (0.5%F.S) |
Control & Safety |
|
Control System |
PC + PLC (custom aging profiles) |
Leakage Protection |
Activates at ≥0.05MPa pressure deviation |
Environment |
|
Ambient Temp. |
10–35℃ (test chamber) |
Relative Humidity |
≤80% RH |
Test Objects & Items
- Test Objects: Gas-fired heating boilers and instantaneous water heaters (≤70kW).
- Core Test Items:
- Aging Simulation: Sanitary (1-30L/min) and heating (1-40L/min) flow cycles.
- Pressure Regulation: Inlet water (0-1.6MPa) and gas (0-10kPa) adjustment.
- Safety Validation: Leakage protection activation, overload shutdown.