WMB-002 is a multi-standard gas boiler-mounted boiler performance testing platform engineered to verify thermal load, energy efficiency, and safety compliance for gas wall-mounted boilers. It integrates 0.5% full-scale precision across heating, sanitary, and gas systems, adhering to GB6932-2015, GB25034-2010, and CJ-series standards, ideal for R&D validation, production line QC, and third-party certification in Singapore and ASEAN markets.
Place of Origin :
ChinaBrand Name :
HONGCECertification :
calibration certificate(cost additional)Model Number :
WMB-002Price :
NegotiatableMOQ :
1 setDelivery Time :
30 daysPayment Terms :
L/C, T/TPackaging Details :
PlywoodSupply Ability :
10 set per monthGas Fired Wall Mounted Boiler Comprehensive Tester 0.5%F.S Precision Gb25034/Gb6932 Compliance
Standard | Scope | Key Test Items |
GB6932-2015 | Domestic gas instantaneous water heaters | Rated thermal load, hot water rise, temperature stability |
GB25034-2010 | Gas-fired heating boilers | Heating efficiency (30%/100% load), circulation pressure |
CJ/T395-2012 | Condensing combi boilers | Condensation efficiency, heat recovery (optional) |
GB2665-2015 | Energy efficiency grading | Thermal efficiency, energy consumption metrics |
Parameter | Specification |
Model | WMB-002 |
Heating System | |
Heating Water Flow | 0–40L/min (0.5%F.S) |
Circulation Pressure | 0–0.6MPa (0.5%F.S) |
Outlet/Return Temp. | 0–100℃ (0.5%F.S) |
Sanitary System | |
Hot Water Flow | 0–30L/min (0.5%F.S) |
Inlet/Outlet Pressure | 0–1.6MPa (0.5%F.S) |
Inlet/Outlet Temp. | 0–100℃ (0.5%F.S) |
Gas System | |
Gas Pressure (Primary) | 0–10kPa (0.5%F.S) |
Gas Pressure (Secondary) | 0–5kPa (0.5%F.S) |
Gas Flow | 0–5m³/h (Dry: 1%F.S; Wet: 0.5%F.S) |
Gas Temperature | 0–50℃ (0.5%F.S) |
Electrical System | |
Voltage | 0–300V (1%F.S) |
Current | 0–4A (1%F.S) |
Environment | |
Air Pressure | 0–1000Pa (1%F.S) |
Atmospheric Pressure | 0–120kPa (1%F.S) |
Hot Tags :