Basic principle:
The equipment using helium as a tracer gas, the workpiece is placed in a vacuum chamber and filled with helium, and the leakage of the relay is judged quickly and accurately through the leak detector.
Certification :
Calibration Certificate(cost additional)Price :
NegotiableDelivery Time :
90 DaysPayment Terms :
L/C, T/TBrand Name :
HCTEModel Number :
HCTE0038Operation Process:
The vacuum chamber closes to commence testing. Firstly, a major leak test is performed. If the vacuum level reaches the set standard, the process continues; otherwise, a major leak is indicated and the process ends. Following this, the vacuum chamber undergoes staged evacuation to achieve the set vacuum level. Subsequently, after suppressing the background signal, helium is filled into the workpiece. During the micro-leak test, if the helium signal detected exceeds the set limit, the micro-leak indicator light illuminates; otherwise, the pass indicator light illuminates. After leak testing is complete, the helium is purged from the workpiece, the vacuum chamber is filled with air, and the piping is purged. Finally, the vacuum chamber opens, and the workpiece is removed. The system supports simultaneous or sequential testing of three chambers (A, B, C), allowing independent or synchronized operation to enhance efficiency.
Product Parameters:
Leak detection stations |
3 Stations |
Leak detection gas |
100% Helium |
Leak detection pressure |
0.5MPa |
Alarm leak rate |
1.0E-9Pa.m³/s |
Production cycle |
24s/ 2 pieces |
Maximum leak detection accuracy |
5.0E-10Pa.m³/s |
Installation Requirements:
Installation must be performed by trained professional installers only.
The on-site installation of the equipment requires the following conditions:
(1) Main Power Supply
Electrical parameters: Three-phase 5-wire 380VAC, power 5KW.
Switch: One air switch, with a height from the ground ≥1.5M, and a distance from the main unit placement position ≤2M.
(2) Gas Sources
① Helium: Bottled helium (40 liters 12MPa) ≥1 bottle, equipped with one 0.6MPa pressure reducing valve;
② High-purity nitrogen: Bottled high-purity nitrogen (≥99.999%), equipped with one 0.2MPa pressure reducing valve;
③ Compressed air: Clean compressed air ≥0.55MPa, equipped with a 1/2″ ball valve;
The distance between the gas source interfaces and the machine placement position should be ≤1M.
(3) Others
① Prepare an outdoor exhaust pipe with a diameter ≥3/4″, and the distance between the interface and the machine placement position should be ≤1M.